Hidrokarbon Çiy Noktası Ölçümü
 | 
| Measuring Technique | 
Dark SpotTM fixed sample analysis. Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature | 
| Sensor Cooling | 
Automatic via 3-stage Peltier effect electronic cooler under adaptive control | 
| Maximum Range | 
Up to Δ 55K measurement depression from Main Unit operating temperature | 
| Accuracy | 
±0.5°C hydrocarbon dew point (single and multiple condensible component analysis)
  | 
Sample Flow
  | 
0.03m³/hr (0.5 Nl/min) - alarm standard | 
| Measurement Frequency | 
6 cycles/hour (recommended) 12 cycles/hour (maximum)
  | 
 
Su Çiy Noktası Ölçümü (İsteğe Bağlı)
 | 
| Measuring Technique | 
Michell Ceramic Moisture Sensor | 
| Units - Moisture content | 
°C and °F water dew point; lb/MMscf; mg/m3, ppmV | 
| Resolution | 
0.1°C, 0.1°F | 
| Range | 
Calibrated from -100 to +20°Cdp | 
| Accuracy | 
±1°C from -59 to +20°Cdp 
  | 
Sample Flow 
  | 
0.06 to 0.3 m3/hr (1 to 5 Nl/min) alarm standard | 
 
Basınç Ölçümü
Hidrokarbon Çiy Noktası Ölçümü
Su Çiy Noktası Ölçümü (İsteğe Bağlı)
 | 
| Units | 
MPa, barg, psig | 
| Resolution | 
0.1 MPa and barg, 1 psig | 
| Range | 
HCdp: 0 to 100 barg Wdp:  0 to 200 barg
  | 
| Accuracy | 
±0.25% FS
  | 
 
Hidrokarbon Çiy Noktası Analizörü
 | 
| Resolution | 
Hydrocarbon and water dew point: 0.1°C | 
| Sample Gas Supply | 
Natural gas up to 100 barg, pressure regulated in sampling system | 
| Enclosure | 
EExd cast enclosure with removable glass window viewing port. Internally heated for condensation protection | 
| Sample Gas Connections | 
1/4" NPT female ports for both hydrocarbon and water dew-point channels; Sampling system: 6mm OD Std / 1/4" OD optional | 
| Operating Environment | 
Indoors/Outdoors -20 to +50°C; Max 95% RH | 
| Power Supply | 
90 to 260 V AC, 50/60 Hz, 125 W Main Unit 300 W c/w Sampling System (indoor) 400 W c/w Sampling system (outdoor) | 
| Weight | 
22.5kg Main Unit 42kg (approx) c/w Sampling System (indoor) 57kg (approx) c/w Sampling system (outdoor) | 
| Integrated Display/Keyboard | 
Touch screen with vacuum fluorescent display | 
Outputs 
  | 
Modbus RTU, RS485 @ 9600 baud rate Two 4-20 mA linear (non-isolated) outputs, user-configurable for any combination of dew-point or pressure parameters | 
| Alarms | 
Process and analyzer status via software register and display annotation Integrated low flow alarms for each sample flow Analyzer status fault flag 23 mA on mA Output 1 | 
 
Sertifikasyon
 | 
| Hazardous Area Certification | 
ATEX / IECEx: II 2G Ex d IIB + H2 Gb Tamb = -40°C to +60°C Tamb -40°C to +60°C T3 CCSAUS certified to Class 1, Div 1, Groups B, C & D, T4 GOST Ex | 
| Pattern Approval | 
GOST-R, GOST-K, GOST-T, ukrSEPRO | 
 
Kapalı Güvenli Alan Montajı için Opsiyonel Uzaktan Arabirim
 | 
| Host Capacity | 
Up to 31 Michell EExd Process Instrumentation Range Analyzers in any combination of models via Modbus | 
| Display | 
Backlit colour 15cm/6" LCD | 
| User Interface | 
Integral mouse, on-screen keyboard | 
| Function | 
View and modify analyzer operating settings; Record parameters to file and view virtual chart recorder analyzer diagnostics | 
| Ports | 
LAN, USB2, Modbus Re-transmission | 
| Data Download | 
CSV (comma separated variable) format for easy import to ExcelTM | 
| Remote Access | 
OPC (OLE for Process Control) over a LAN Imbedded web page/unique IP address for PC access Remote data reading via Modbus RTU | 
| Power Supply | 
100 to 280 V, 50/60 Hz | 
Plant Control Integration
  | 
ActiveX components to be used by software programmers for integration of Modbus protocol into a general plant software system |