 Kullanım alanı: Güç, enerji, nükleer, kağıt prosesi, ulaşım, denizcilik, metalurji. Ürün Özellikleri 
 | 
Ürünler  | 
PR285  | 
|
| Performans Özellikleri | ||
| RH Measurement Range | 
0 to 100% RH | 
|
| RH Accuracy @ 23°C | ±2% RH (5 to 95% RH) | 
|
| RH Measurement Response Time | 
<10 seconds | |
| RH element | 
H8000 | |
| Elektriksel Özellikler | ||
| Output signals | 0–1 V, 0–5 V, 0–10 V, 4–20 mA, 0–20 mA | 
|
| Supply voltage range | 
15 to 21 V AC or 18 to 30 V DC | 
|
| Power consumption | 1.7 W max | 
|
| CE conformity | 
2004/108/EC, 94/9/E | 
|
| Communication kit (optional) | 
Digicor2 280/290 software, USB to RS485 interface cable (Digicor2-CK-01) | 
|
| Çalışma Koşulları | ||
| Operating temperature | 
UTSE Probe: UTSE Cable: Housing: Storage:  | 
–40 to +120°C –40 to +120°C –30 to +70°C –40 to +70°C  | 
| Mekanik Özellikler | ||
| Ingress protection | 
IP65 (NEMA 4 level) | 
|
| Material | UTSE Probe: UTSE Cable: Housing:  | 
Stainless stell PTFE white Aluminum die casting  | 
| Dimensions | 
USTE Probe: USTE Cable: Housing:  | 
L=148mm, ø18mm L=2m (optional extra 2m) 120 x 120 x 49.5mm  | 
| Weight | 
450g (approx) | 
|
| Electrical connections | Internal screw terminals | 
|